Sign In | Join Free | My burrillandco.com
Home > Laminar Clean Bench >

110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

Shenzhen Zhong Jian South Environment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter from wholesalers
     
    Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter from wholesalers
    • Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter from wholesalers

    110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

    Ask Lasest Price
    Brand Name : ZJNF
    Model Number : ZJNF-1
    Certification : CE
    Price : negotiate
    Payment Terms : tt lc PayPal credit card
    Delivery Time : 18 days
    • Product Details
    • Company Profile

    110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

    Here is the professional English translation of the layered ultra-clean workbench description:


    Laminar Flow Clean Bench
    A laminar flow clean bench utilizes a high-efficiency air filtration system to generate unidirectional airflow (vertical or horizontal), creating a localized high-cleanliness operating environment. Its core function is to protect samples from contamination. Key features and applications are as follows:

    I. Core Principles & Structure

    1. Laminar Flow Mechanism
      Room air is pre-purified by a primary filter, pressurized into a plenum chamber via a blower, and then filtered through a HEPA filter to form stable unidirectional airflow (vertical or horizontal)
      • Vertical Laminar Flow‌: Top-down airflow prevents direct exposure to operators; ideal for high-risk biomedical applications
      • Horizontal Laminar Flow‌: Horizontal outward airflow offers larger workspace; commonly used in electronics
    2. Cleanliness Class
      Work zone achieves Class 100 (ISO Class 5) cleanliness: ≤3.52 particles (≥0.5μm) per liter
    3. Core Components
      Include primary/HEPA filters, blower, stainless steel work surface, UV germicidal lamp, and smart control system (e.g., touchscreen for wind speed adjustment)

    II. Classification & Selection

    Classification BasisTypeCharacteristics
    Airflow DirectionVertical Laminar FlowTop-down airflow; high operator safety; suitable for biological labs
    Horizontal Laminar FlowLarger workspace; lower noise; preferred in electronics
    Operation StructureSingle-person single-sideSingle blower; lower noise
    Dual-person single-sideDual blowers; moderate noise increase
    Dual-person dual-sideEnables collaboration; requires larger space
    Special DesignsRecirculating TypeNo external ducts; flexible deployment in non-clean areas
    Benchtop TypeSpace-saving; ideal for compact labs

    III. Primary Applications

    • Biomedicine‌: Cell culture, vaccine preparation, aseptic preparation filling (contamination rate <0.8%)
    • Medical Testing‌: Virus isolation, nucleic acid detection (prevents aerosol contamination)
    • Precision Manufacturing‌: Electronic component assembly, optical instrument production (anti-dust/anti-static)
    • Food & Research‌: Microbial testing, gene editing (e.g., CRISPR), ensures experimental accuracy

    IV. Operation & Maintenance Guidelines

    1. Environmental Requirements
      Temperature: 5–35°C; humidity ≤85%; avoid dusty/explosive environments
    2. Safe Operation
      • Sterilize with UV light for 30 mins before use; keep glass sash partially closed during operation
      • Regularly monitor wind speed (0.3–0.6m/s for vertical flow) and filter pressure differential
    3. Maintenance Cycle
      • Clean primary filter monthly; replace HEPA filter every 2–3 years (varies by environment)
      • Equipment lifespan correlates with air cleanliness; shorter intervals in tropical regions

    V. Technology Evolution

    Modern models (e.g., VD-650) feature smart controls for stepless wind speed adjustment and real-time pressure display; DC motors reduce energy consumption by 30%, while stainless steel enhances corrosion resistance. High-end units include dynamic airflow monitoring to limit speed fluctuations to ≤20%


    Technical Data


    MODELZJNF-1ZJNF-2ZJNF-3ZJNF-4
    Table Size(mm)1200*600*7401200*600*1500600*600*7401800*600*1460
    Fan Size(mm)1200*600*7401175*575*320575*575*3201175*575*320
    MaterialAluminum / Stainless Steel
    Efficiency99.99% @ 0.3um

    Product Details

    110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter


    Quality 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Zhong Jian South Environment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)